Work instructions for live working
An additional service of ours is the development of work instructions and work orders for live working.
Down below you can find an overview of some of our work instructions.
We can deliver the work instructions in a printed form and on CD-ROM.
Overview of some of our valid work instructions for live working
Basic instruction low voltage
Description |
No. of work instruction |
Basic instruction low voltage |
AW-LV 1 |
Live cable work
Description |
No. of work instruction |
Cutting of oil-paper insulated cables N(A)KBA |
AW-LV 2/01 |
Cutting of plastic cables with Ceander outer conductor N(A)YCWY |
AW-LV 2/02 |
Assembly of insulating cable end joints for oil-paper insulated cables N(A)KBA |
AW-LV 2/03 |
Assembly of branch tees for oil-paper insulated cables N(A)KBAwith separated terminals in insulating box |
AW-LV 2/04 |
Assembly of branch tees for plastic cables N(A)YY with clamping ring |
AW-LV 2/05 |
Assembly of insulating wire end joints for plastic cables N(A)YY |
AW-LV 2/06 |
Assembly of shrink joints for plastic cables N(A)YY with bolted connections |
AW-LV 2/07 |
Cutting of plastic cables N(A)YY |
AW-LV 2/08 |
Assembly of shrink joints for plastic cables N(A)YY |
AW-LV 2/09 |
Assembly of transition joints from oil-paper insulated cables N(A)KBA to plastic cables N(A)YY with shrink technology |
AW-LV 2/10 |
Assembly of branch tees plastic cables with Ceander outer conductor N(A)YCWY (three conductor cable) with clamping ring |
AW-LV 2/11 |
Assembly of transition joints from oil-paper insulated cables N(A)KBA to plastic cables N(A)YY in insulating box |
AW-LV 2/12 |
Assembly of shrink joints for plastic cables with Ceander outer conductor N(A)YCWY with bolted connections |
AW-LV 2/13 |
Assembly of transition joints from oil-paper insulated cables N(A)KLEY to plastic cables N(A)YY with shrink technology |
AW-LV 2/14 |
Assembly of branch tees for oil-paper insulated cables N(A)KLEY with clamping ring |
AW-LV 2/15 |
Assembly of transition joints from oil-paper insulated cables N(A)KLEY to plastic cables N(A)YY in insulating box |
AW-LV 2/16 |
Assembly of branch tees for oil-paper insulated cables N(A)KBA with clamping ring |
AW-LV 2/17 |
Assembly of shrink joints for plastic cables with concentric outer conductor NAYFaY |
AW-LV 2/18 |
Assembly of shrink joints for plastic cables with Ceander outer conductor N(A)YCWY with crimp connectors |
AW-LV 2/19 |
Check zero-potential at oil-paper insulated cables N(A)KBA |
AW-LV 2/20 |
Check zero-potential at plastic cables N(A)YY |
AW-LV 2/21 |
Cutting of oil-paper insulated cables N(A)KLEY with Aluminium sheath |
AW-LV 2/22 |
Cutting of plastic cables with concentric outer conductor NAYFaY |
AW-LV 2/23 |
Assembly of insulating cable end joints for plastic cables with Ceander outer conductor N(A)YCWY |
AW-LV 2/24 |
Assembly of insulating cable end joints for oil-paper insulated cables N(A)KLEY with Aluminium sheath in insulating box |
AW-LV 2/25 |
Assembly of insulating cable end joints for plastic cables with concentric outer conductor NAYFaY |
AW-LV 2/26 |
Assembly of branch tees for plastic cables with concentric outer conductor NAYFaY with separated terminals in a insulating box |
AW-LV 2/27 |
Assembly of branch tees for oil-paper insulated cables N(A)KLEY with separated terminals in a insulating box |
AW-LV 2/28 |
Work on switchgear
Description |
No. of work instruction |
Replacement of fuse devices |
AW-LV 3/01 |
Connect and reconnect of cable and wires in LV-switchgear |
AW-LV 3/02 |
Replace of house supply boxes |
AW-LV 3/03 |
Replace of LV strip-type fuseways and strip-type fuse-disconnectors |
AW-LV 3/04 |
Dry cleaning of LV-switchgear |
AW-LV 3/05 |
Retightening of bolted connections in LV-switchgear |
AW-LV 3/06 |
Remove of scaled contacts at strip-type fuseways |
AW-LV 3/07 |
Upgrading busbars at LV-switchgear |
AW-LV 3/08 |
Wet cleaning of LV-switchgear |
AW-LV 3/09 |
Work at overhead lines (OHL)
Description |
No. of work instruction |
Assembly and disassembly of overhead line house supplies at branch pylons |
AW-LV 4/01 |
Assembly and disassembly of house supply cables and air cables (isolated overhead lines) |
AW-LV 4/02 |
Assembly and disassembly from cables on overhead lines at pylons |
AW-LV 4/03 |
Assembly of insulation for building activities |
AW-LV 4/04 |
Assembly and disassembly of temporary power supply devices |
AW-LV 4/05 |
Assembly and disassembly of branch fuses |
AW-LV 4/06 |
Assembly and disassembly of surge arresters |
AW-LV 4/07 |
Open and close of bridging lines at branch pylons |
AW-LV 4/08 |
Repair of damaged wires of overhead lines |
AW-LV 4/09 |
Maintenance and replace of defect disconnector contacts |
AW-LV 4/10 |
Release and assembly of cross tie while changing wooden pylons |
AW-LV 4/11 |
Replace of insulators and supports at pylons and roofs |
AW-LV 4/12 |
Assembly and disassembly of house supplies with isolated OHL wires NFA2X |
AW-LV 4/13 |
Work at metering systems
Description |
No. of work instruction |
Work at metering and accessory systems |
AW-LV 5/01 |
Work at LV electric meter and instrument transformer systems |
AW-LV 5/02 |
Technical locking of house supplies |
AW-LV 5/03 |
Work at measurement and control technology systems
Description |
No. of work instruction |
Work at terminal strips |
AW-LV 6/01 |
Assembly and disassembly of devices with bolted connection interface |
AW-LV 6/02 |
Release and assembly of wire connections at support busbars |
AW-LV 6/03 |
Temporary connection of measurement devices |
AW-LV 6/04 |
Work at street lighting installation
Description |
No. of work instruction |
Connect and reconnect of cables in transition and fuse boxes |
AW-LV 7/01 |
Assembly and disassembly of switchboards in cubicles |
AW-LV 7/02 |
Assembly of shrink joints for plastic cables N(A)YY with bolted connections |
AW-LV 7/03 |
Work at electric installations
Description |
No. of work instruction |
Work at electric installations |
AW-LV 11 |
Work at battery and DC systems
Description |
No. of work instruction |
Replace of batteries |
AW-LV 12/01 |
Connect and reconnect of DC cables and wires |
AW-LV 12/02 |
Basic instruction medium voltage cleaning and maintenance
Description |
No. of work description |
Dry cleaning of indoor equipment up to 36 kV |
AW-HV 3/01 |
Damp cleaning of indoor equipment up to 36 kV |
AW-HV 3/02 |
Refilling of oil terminations up to 36 kV |
AW-HV 3/03 |
Maintenance of switching devices up to 36 kV |
AW-HV 3/04 |
Creating by-pass for 24 kV switching devices with BSD jumpering system |
AW-HV 3/05 |
Inspection of non-view-able parts with BSD insulating camera |
AW-HV 3/06 |
Creating by-pass for 12 kV switching devices with BSD jumpering system |
AW-HV 3/07 |
Basic instruction medium voltage hot stick method overhead line
Description |
No. of work instruction |
Assembly and Disassembly of short-circuit indicators |
AW-HV 4/01 |
Mounting and removing of bird protection caps |
AW-HV 4/02 |
Mounting and removing of BSD perch rejectors |
AW-HV 4/03 |
Basic instruction medium voltage work with insulating gloves
Description |
No. of work instruction |
Assembly and disassembly of supporting insulators at the pole |
MSFL 2/01 |
Assembly and disassembly of supporting insulators in double support variant at the pole |
MSFL 2/02 |
Modification from single support to double support construction at the pole |
MSFL 2/03 |
Assembly and disassembly of tension insulators at the pole |
MSFL 2/04 |
Assembly and disassembly of suspension insulators at the pole |
MSFL 2/05 |
Modification from supporting insulator to suspension insulator construction at the pole |
MSFL 2/06 |
Opening and closing of current bridges at the pole |
MSFL 2/07 |
Assembly and disassembly of bird protection caps with insulating gloves |
MSFL 2/09 |
Removal of foreign objects from poles with supporting insulator construction |
MSFL 2/10 |
Repairing of conductor damages |
MSFL 2/11 |
Assembly and disassembly of disconnectors |
MSFL 2/12 |
Draft(Changing of wooden poles with supporting insulators and T-type traverse |
MSFL 2/15 |
Covering for work at non-active parts |
MSFL 2/17 |
Changing of wooden poles with suspension insulators and T-type traverse |
MSFL 2/19 |
Changing of wooden poles with vertically offset supporting insulators |
MSFL 2/20 |
Changing of wooden poles with vertically offset suspension insulators |
MSFL 2/21 |